Sign In | Join Free | My burrillandco.com
Home > Air Differential Pressure Transmitter >

2 Wire 4-20mA ABB Differential Pressure Transmitter Sensor For Pharmaceutical Clean Rooms

    Buy cheap 2 Wire 4-20mA ABB Differential Pressure Transmitter Sensor For Pharmaceutical Clean Rooms from wholesalers
     
    Buy cheap 2 Wire 4-20mA ABB Differential Pressure Transmitter Sensor For Pharmaceutical Clean Rooms from wholesalers
    • Buy cheap 2 Wire 4-20mA ABB Differential Pressure Transmitter Sensor For Pharmaceutical Clean Rooms from wholesalers
    • Buy cheap 2 Wire 4-20mA ABB Differential Pressure Transmitter Sensor For Pharmaceutical Clean Rooms from wholesalers
    • Buy cheap 2 Wire 4-20mA ABB Differential Pressure Transmitter Sensor For Pharmaceutical Clean Rooms from wholesalers
    • Buy cheap 2 Wire 4-20mA ABB Differential Pressure Transmitter Sensor For Pharmaceutical Clean Rooms from wholesalers

    2 Wire 4-20mA ABB Differential Pressure Transmitter Sensor For Pharmaceutical Clean Rooms

    Ask Lasest Price
    Brand Name : KeramControls
    Model Number : KDP210
    Certification : CE
    Price : $69-$51/pic
    Payment Terms : T/T, L/C
    Supply Ability : 2000pic/month
    Delivery Time : 7-10days
    • Product Details
    • Company Profile

    2 Wire 4-20mA ABB Differential Pressure Transmitter Sensor For Pharmaceutical Clean Rooms

    2 Wire 4-20mA ABB Differential Pressure Transmitter Sensor For Pharmaceutical Clean Rooms

    Description


    The differential pressure transmitter is a transmitter that measures the pressure difference between the two ends of the transmitter, and outputs standard signals (such as 4~20mA, 0~5V). Differential pressure transmitters are different from general pressure transmitters in that they have 2 pressure interfaces. Differential pressure transmitters are generally divided into positive pressure ends and negative pressure ends. Under normal circumstances, differential pressure transmitters have positive pressure The pressure at the end should be greater than the pressure in the negative pressure section to measure.


    Feature


    • Ranges from -25/+25Pa to -10000/+10000Pa (according to models)
    • Auto zero manual calibration
    • Voltage, current, digital signal output
    • Standard accuracy <±1% FS
    • IP65 house protection
    • When ≤100Pa,accuracy<±3%FS±2Pa

    Application


    • HVAC system
    • Pharmaceutical clean rooms
    • Electronic clean rooms
    • Medical clean rooms
    • Commercial buildings
    • Public transport hub

    Technical data


    ModelKDP210
    Measurement UnitsPa,mmH2O,inWG,mmHG,KPa,mbar
    Accuracy<±1% FS@-5 to +65℃
    Response Time0.5s
    Repeat Stability±0.01 % at FS /Year
    Resolution0.1 Pa; 0.1 mmH2O; 0.01mbar; 0.01mmHG
    MediaAir and neutral gases
    Operating Temperature-20…+70℃
    Storage Temperature-40…+60℃
    Power Consumption<1.5W
    Tolerated over pressurex15
    Power Supply16~30VAC/DC (3wire) / 18~30VDC (2wire)
    Output Signal4-20mA(2wire)
    4-20mA(3wire)
    0~5V/0~10VDC(3wire)
    RS-485
    Customized
    Auto ZeroManual calibration
    Housing MaterialPC&ABS,UL94V-0
    Protection ClassIP65/NEMA4
    DisplayBacklight LCD display(4-20mA 2 wire without backlight)
    Cable GlandM16*1.5

    Dimension(mm)


    2 Wire 4-20mA ABB Differential Pressure Transmitter Sensor For Pharmaceutical Clean Rooms

    2 Wire 4-20mA ABB Differential Pressure Transmitter Sensor For Pharmaceutical Clean Rooms


    Measuring range adjustment


    2 Wire 4-20mA ABB Differential Pressure Transmitter Sensor For Pharmaceutical Clean Rooms


    Output setting(3 wire Model)


    2 Wire 4-20mA ABB Differential Pressure Transmitter Sensor For Pharmaceutical Clean Rooms


    Manual Zero-point correction


    2 Wire 4-20mA ABB Differential Pressure Transmitter Sensor For Pharmaceutical Clean Rooms


    Ordering guide


    KDP210-Range-display-output


    ModelRangesDisplayoutput
    KDP210-100~+100Pa(1)LCD backlight(D)4-20mA(2 wire)(E)
    -1000~+1000Pa(2)4-20mA(3 wire)(F)
    -2000~+2000Pa(3)0-5/0-10VDC (3 wire)(G)
    -10000~+10000Pa(4)RS-485(H)
    Customized

    2 Wire 4-20mA ABB Differential Pressure Transmitter Sensor For Pharmaceutical Clean Rooms2 Wire 4-20mA ABB Differential Pressure Transmitter Sensor For Pharmaceutical Clean Rooms

    2 Wire 4-20mA ABB Differential Pressure Transmitter Sensor For Pharmaceutical Clean Rooms

    FAQ


    1 Q: What's the delivery time?

    A: According to the specification and quantity of your order, generally 4

    days for normal standard products within 10pcs.


    2 Q:Are you manufacturer or trading company?

    A: We are manufacturer with many years of experience.We have our

    own factory.Welcome to visit our factory.


    3 Q: Can we use our logo on the products?

    A: Yes.We can provide OEM service.


    4 Q: Do you have products with ex-proof certificate?

    A: Yes,we can offer intrinsic-safety and flame proof certificates.


    5 Q: What is the warranty of your products?

    A: Normal is 12 months.


    6 Q: What's the means of transport?

    A: Express such as TNT,Fedex,DHL,UPS, or logistics by indicator.


    Quality 2 Wire 4-20mA ABB Differential Pressure Transmitter Sensor For Pharmaceutical Clean Rooms for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Keram (Nanjing)ELECTRICAL Equipment Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)